Indelec Prevectron 3 S60 ESE Air Terminal – P1543
The Indelec Prevectron® 3 S60 (P1543) is the flagship model of the Prevectron® 3 range of Early Streamer Emission (ESE) lightning conductors. With a 60 µs advance time (ΔT), the longest in the range, it is designed for projects where one air terminal must protect the largest possible area: industrial plants, warehouses, logistics hubs, stadiums, hospitals, schools and open sites. Indelec describes the Prevectron® 3 range as the first ever UL-certified ESE air terminal, combining French lightning protection technology with North American safety certification.
How the Prevectron 3 S60 Works
An ESE air terminal triggers an upward streamer earlier than a conventional lightning rod. That early streamer lets it intercept the downward leader first and extends the protected area around the mast. The Prevectron 3 S60:
- Detects an approaching storm by continuously measuring the electric field gradient (ΔE/Δt).
- Triggers the upward streamer through 6 independent, synchronised internal modules, the most in the Prevectron® 3 range.
- Optimises triggering with OptiMax® technology, developed by Indelec’s Lightning Innovation and Research Institute (LiRi). OptiMax® neutralises the space charges around the conductor before the upward streamer is released.
Built for Harsh Outdoor Environments
The housing is 316 stainless steel with electromagnetic shielding, and the 200 mm² nickel-plated copper central rod ensures full electrical continuity to the down conductor. The S60 is tested to a normative lightning current of 100 kA and has withstood a maximum current test of 230 kA (Unicamp). It fixes to the pole with a standard M20 thread and carries a 5-year warranty.
Certified to International Standards
The Prevectron 3 S60 is certified to NF C 17-102:2011 Annex C by Bureau Veritas, holds Qualifoudre certification from Ineris, and is UL certified (file E478687). Indelec manufactures it in France under an ISO 9001:2015 quality system. It is CE marked, 100% recyclable, and carries the AFAQ eco-label.
Prevectron 3 Range: Which Model Do You Need?
| Model | Part number | Advance time (ΔT) | Modules | Imax |
|---|---|---|---|---|
| Prevectron 3 S40 | P1523 | 40 µs | 3 | 200 kA |
| Prevectron 3 S50 | P1533 | 50 µs | 4 | 200 kA |
| Prevectron 3 S60 | P1543 | 60 µs | 6 | 230 kA |
The longer the advance time, the larger the protection radius at a given mast height. The final choice depends on the protection level and the lightning risk assessment of each project.
Complete the Installation
After a lightning strike, a lightning protection system must be inspected. Adding an Indelec Digital Flash Lightning Counter (P8011) on the down conductor records every strike, so you know when an inspection is due.
P1543 Technical Data
| Specification | Value |
|---|---|
| Manufacturer | Indelec (France) |
| Part number | P1543 |
| Product | Prevectron® 3 S60 ESE air terminal |
| Advance time (ΔT) | 60 µs |
| Detection principle | Continuous measurement of electric field gradient (ΔE/Δt) |
| Internal modules | 6 independent, synchronised |
| Triggering technology | OptiMax® |
| Normative lightning current | Iimp 100 kA |
| Max. current withstanding test | Imax 230 kA (Unicamp) |
| Housing | Stainless steel 316, electromagnetic shielding |
| Central rod | 200 mm², nickel-plated copper, full electrical continuity |
| Pole fixing | M20 thread |
| Net / gross weight | 3.9 kg / 5.65 kg |
| Packed dimensions | 438 x 228 x 220 mm |
| Warranty | 5 years |
| Standards & certifications | NF C 17-102:2011 Annex C (Bureau Veritas), Qualifoudre (Ineris), UL E478687, ISO 9001:2015, CE, AFAQ eco-label |
| Recyclability | 100% recyclable |
Frequently Asked Questions
What does “S60” mean on the Prevectron 3?
It refers to the 60 µs advance time (ΔT): how much earlier the terminal triggers its upward streamer than a simple rod under the same conditions. It is the longest advance time in the Prevectron® 3 range.
What is the difference between the Prevectron 3 S40, S50 and S60?
They share the same housing, OptiMax® technology and certifications. The S40 has a 40 µs advance time and 3 modules, the S50 has 50 µs and 4 modules, and the S60 has 60 µs and 6 modules, which gives the widest protection radius of the three.
Is the Prevectron 3 S60 UL certified?
Yes. The Prevectron® 3 range is UL certified under file E478687, and Indelec presents it as the first ESE air terminal to receive UL certification.
Which standard does the Prevectron 3 S60 comply with?
It is certified to the French ESE standard NF C 17-102:2011 (Annex C) by Bureau Veritas, and holds Qualifoudre certification from Ineris.
How is the Prevectron 3 S60 installed?
It screws onto the top of the mast with an M20 thread and connects to the down conductor through its central rod. Indelec publishes typical installation schematics for the Prevectron® 3 range.
Buy the Indelec P1543 Prevectron 3 S60 from Atlantech Drives
Atlantech Drives supplies genuine Indelec lightning protection products to contractors, engineering firms and facility managers worldwide. Our experienced sales team can confirm availability, lead time and pricing, and help you put together a complete order with lightning counters and related Indelec products. Request a quote today for fast international shipping.
Product status: Active, listed as a current product by Indelec.
Suggested Internal Linking
- Other Prevectron 3 models: S40 – P1523, S50 – P1533
- Lightning strike counter: Indelec Digital Flash – P8011
- Other Indelec products (if you list them): Prevectron® 3 S60 Connect, Prevectron® 3 TS25, PrimeR® Heritage Building