Buy 101213954 Schmersal AZM 300Z-I2-ST-1P2P RFID High Coding

Purchase now: Schmersal 101213954 AZM 300 High-Coded Interlock

Purchase now: Atlantech Drives provides you the Schmersal 101213954 (Model: AZM 300Z-I2-ST-1P2P), the ultimate solution for high-security machine guarding. This **Solenoid Interlock** utilizes the innovative **Rotating Cross** locking mechanism and **RFID technology**. The critical feature of this «I2» model is **Individual Coding (High Level)**. This means the switch learns the specific code of its actuator during commissioning and will **not accept any other actuator**, preventing operators from bypassing the safety system using a spare key (a common violation in factories).

Technical Specifications and Anti-Tamper Design

The AZM 300 is rated **IP 69K**, making it suitable for high-pressure cleaning in food and pharma industries. It offers a holding force of **1,150 N**. The «1P2P» configuration provides **2 Safety Outputs (OSSD)** and **1 Diagnostic Output**. The «I2» coding allows for **Multiple Teaching**: if you lose the actuator, you can teach a new one, but the old one becomes permanently invalid (requires a 10-minute timeout penalty to prevent fraud).

  • Part Number: 101213954.
  • Model: AZM 300Z-I2-ST-1P2P.
  • Coding Level: High (ISO 14119) – Individual I2.
  • Locking: Solenoid with Rotating Cross.
  • Holding Force: 1,150 N.
  • Adjustable Latching: 25N or 50N.
  • Protection: IP 69K (Hygienic).
  • Connection: M12, 8-pole.

Expert Maintenance Tips: The 10-Minute Rule

If you need to replace the actuator on an «I2» unit, do not panic if it doesn’t work instantly. Expert Tip: When teaching a new actuator, the AZM 300 initiates a 10-minute blocking period to discourage tampering. You must leave the supply voltage ON during this time. The LED will flash. Only after the time elapses can the new code be saved by cycling power. Do not turn off the machine mid-process!

Frequently Asked Questions (FAQs)

Q: What is the difference between I1 and I2 coding?
A: «I1» can only be taught once (forever). «I2» can be re-taught multiple times (with the new replacing the old), offering flexibility if a door is damaged.

Q: Can I use this for PLe applications?
A: Yes, the RFID OSSD outputs are certified for Category 4 / PLe / SIL 3 safety circuits.

Do you need more references from this brand? Explore our full catalog of Schmersal here.

Check Price & Availability!

Get a fast, no-obligation quote for this part.

Our technical team responds within 24-48 hours.

  • Express Worldwide Shipping
  • 100% Genuine OEM Parts

We can supply you this part. Just get in touch!

Logo Pagos Seguros