RP-3A-2G-Y-8 Winner Hydraulics: 200 L/min Balanced Poppet Relief Valve with 8A Pilot Cavity
The Winner Hydraulics RP-3A-2G-Y-8 is a high-flow, pilot-operated relief cartridge for the 3A-2 cavity. It handles up to 200 L/min at 350 bar. Its main stage uses a balanced poppet and includes a built-in 8A-2 cavity, so any 8A-2 pressure control cartridge can act as the pilot. That combination gives a single, compact assembly for remote or electro-proportional pressure regulation on higher-flow circuits.
Operating Principle
Port 1 is the inlet and port 2 is the outlet. Once inlet pressure overcomes the setting of the 8A-2 pilot cartridge, the main poppet lifts and meters flow from port 1 to port 2 to regulate pressure. The pilot setting determines the pressure differential between the two ports. Back pressure at port 2 adds to the setting on a 1:1 basis.
RP-3A-2G-Y-8 Technical Data
| Parameter | Value |
|---|---|
| Function | Pilot-operated balanced poppet relief, main stage with integral 8A control cavity |
| Cavity | 3A-2 |
| Pilot cavity | 8A-2 |
| Rated flow | 200 L/min (52.83 gpm) |
| Max. operating pressure | 350 bar (5000 psi) |
| Thread | 1.0″-14UNS-2A |
| Hex size | 28.57 mm (1-1/8 in) |
| Installation torque | 60–70 Nm (44–52 lbf-ft) |
| Typical response time | 7 ms |
| Max. leakage | Approx. 0.7 cc/min, main stage at reseat |
| Weight | 0.18 kg (0.4 lb) |
| Spring codes (Y) | B: 3.5 bar (50 psi) min. control pressure; W: 7 bar (100 psi) min. control pressure |
Design Highlights
- Balanced poppet main stage: limits cavitation, noise and manifold erosion when pressure drop across the valve is high
- W spring: specified by Winner for higher pressure-drop applications
- Protected pilot port: a stainless-steel filter screen improves contamination resistance
- Full-pressure outlet: port 2 is rated for full system pressure
- Hardened internals: heat-treated, high-precision ground working parts
- Corrosion protection: WINNERcoat® zinc-nickel plating, up to 1000 hours salt-spray tested to DIN EN ISO 9227
- Verified durability: pressure rating tested to NFPA T2.6.1, with 90/90 fatigue rating assurance
- Quality assured: every cartridge is 100% functionally tested before dispatch
- Seal choices: several seal kit materials offered for different fluids and conditions
Proportional Pilot Options for the RP-3A-2G-Y-8
Winner lists these 8A-2 electro-proportional pilot relief valves as typical partners for the RP-3A-2G-Y-8:
- PRB-8A-2D-Y-Z and PRB-8A-2C-Y-Z: direct-acting proportional pilot relief
- PRA-8A-2C-Y-Z and PRA-8A-2D-Y-Z-74: inverse direct-acting proportional pilot relief
Where the RP-3A-2G-Y-8 Sits in the RP-2G-8 Range
With twice the rated flow of the 10A-2 versions, the RP-3A-2G-Y-8 is the mid-size option in Winner’s RP-2G-8 series:
- RP-10W-2G-Y-8 / RP-10A-2G-Y-8: 95 L/min
- RP-3A-2G-Y-8: 200 L/min, 3A-2 cavity
- RP-16A-2G-Y-8: 380 L/min
- RP-18A-2G-Y-8: 760 L/min
Order the RP-3A-2G-Y-8 Winner Hydraulics Today
Atlantech Drives supplies genuine Winner Hydraulics cartridge valves to customers worldwide, with fast shipping. Our commercial team will confirm stock, spring code (B or W), seal material and delivery time for your RP-3A-2G-Y-8, whether you need a single replacement or a production quantity. Get a quote now.