PPD-11A-3D-Y-Z-74-3 Winner Hydraulics Proportional Reducing/Relieving Valve with Open-Overlap Spool
The Winner Hydraulics PPD-11A-3D-Y-Z-74-3 is a direct-acting, spool-type electro-proportional pressure reducing/relieving valve with improved dynamic response, for the 3-port 11A-3 cavity. Like the rest of the PPD family, it gives low pressure with no command, and the reduced pressure rises in proportion to coil current. What sets the -74-3 apart is its spool geometry. Where the standard PPD-11A-3D-Y-Z-74 closes between reducing and relieving, the -74-3 uses a slight open overlap during that transition, which Winner specifies to ensure stable pressure control. It is rated for 20 L/min at 350 bar and protected by US patent US9234605.
How the PPD-11A-3D-Y-Z-74-3 Works
Oil flows from port 2 (inlet) to port 1 (reduced pressure) at the level set by the coil current. If pressure at port 1 exceeds the setting, the valve relieves from port 1 to port 3 (drain). During the change from reducing (2 to 1) to relieving (1 to 3), the slight open overlap keeps pressure control stable. Winner notes that this may cause a pilot flow loss of approximately 200 cc/min, particularly during transitions under dead-head conditions.
PPD-11A-3D-Y-Z-74-3 Technical Data
| Specification | Value |
|---|---|
| Valve type | Direct-acting, spool-type, electro-proportional pressure reducing/relieving valve, improved dynamic response |
| Function | Low pressure with no command |
| Spool transition | Slight open overlap between reducing and relieving, for stable pressure control |
| Cavity | 11A-3 (3-port) |
| Thread | M20 x 1.5 |
| Ports | 1 reduced pressure, 2 inlet, 3 drain |
| Rated flow | 20 L/min (5.28 gpm) |
| Max. operating pressure | 350 bar (5000 psi) |
| Valve hex size | 22.22 mm (7/8 in) |
| Installation torque | 40–50 Nm (30–37 lbf-ft) |
| Max. leakage | Approx. 400 cc/min at port 3 (port 2 at 350 bar, port 1 set to 35 bar) |
| Transition pilot flow loss | Approx. 200 cc/min (particularly under dead-head conditions) |
| Linearity / repeatability with dither | < 2% / < 2% |
| Hysteresis | < 4% with dither; < 8% with DC input |
| Recommended dither | 100–250 Hz (best 140–200 Hz) |
| Coil | EC-19A, 22 W, 19 mm tube |
| Weight | 0.259 kg without coil / 0.499 kg with coil |
| Patent | US9234605 |
Operating Ranges (Y)
| Y code | Reduced pressure range |
|---|---|
| 3500 | 35–350 bar |
| 2100 | 20–210 bar |
| 1500 | 10–150 bar |
| 1000 | 10–100 bar |
| 0800 | 2–80 bar |
| 0350 | 1–35 bar |
| 0180 | 1–18 bar |
| 0090 | 1–9 bar |
Options (Z)
- N: non-adjustable
- P: push-style manual override
Features
- Open-overlap spool transition for stable pressure control
- Reduced pressure increases with current, from low pressure at zero command
- Improved dynamic response
- Reducing and relieving functions in one 3-port cartridge
- Can operate below 1 bar
- Eight operating ranges, from 1 bar to 350 bar
- Non-adjustable or manual override versions
- Patented design (US9234605)
- Heat-treated, high-precision ground working parts
- WINNERcoat® zinc-nickel plating, salt-spray tested to DIN EN ISO 9227 for up to 1000 hours
- Pressure rating tested to NFPA T2.6.1, with 90/90 fatigue rating assurance
- 100% functionally tested before shipment
- Seal kit materials to suit different applications
Manufacturer Notes
- Back pressure at port 3 adds to the valve setting at a 1:1 ratio.
- With inlet pressures of 210–350 bar, Winner recommends a minimum reduced pressure of 30 bar at port 1 for best control.
- If a wide range (Y = 1000, 1500, 2100 or 3500) must also control pressure below 10 bar, contact us so we can confirm the options with Winner.
- A current-sensing amplifier with dither is recommended.
Choosing Between the PPD-11A-3D Versions
| Model | Reducing/relieving transition | Max. leakage | Stated suitability |
|---|---|---|---|
| PPD-11A-3D-Y-Z-74-3 | Slight open overlap (stable pressure control) | Approx. 400 cc/min (350 bar supply) | Stable pressure control |
| PPD-11A-3D-Y-Z-74 | Spool closes to minimise oil consumption | Approx. 40 cc/min (210 bar supply) | General use |
| PPD-11A-3D-Y-Z-74-1 | Spool closes; low-leakage design | Approx. 20 cc/min (210 bar supply) | Brake circuits |
All three share the 11A-3 cavity, 20 L/min rating, 350 bar maximum pressure, EC-19A coil and the same eight operating ranges. For high pressure at zero current, see the PPC-11A-3D-Y-Z-74.
Buy the PPD-11A-3D-Y-Z-74-3 Winner Hydraulics
Atlantech Drives supplies genuine Winner Hydraulics electro-proportional valves worldwide, with fast shipping. Tell us the operating range, the option (N or P) and the coil voltage, and our commercial team will quote the PPD-11A-3D-Y-Z-74-3 with availability and lead time. Request your quote today.