DG4V-5-2A-M-P7-H-7-10 Tokio Keiki Solenoid Valve | High-Pressure G05 Directional Control

Tokio Keiki DG4V-5-2A-M-P7-H-7-10 Solenoid Valve

The DG4V-5-2A-M-P7-H-7-10 is a high-performance, solenoid-operated directional control valve manufactured by Tokio Keiki (formerly Tokimec). This wet-armature type valve is designed for gasket mounting according to the ISO 4401-05 (Cetop 5) interface. The «2A» configuration identifies it as a two-position, single-solenoid valve with a spring-offset arrangement, making it ideal for applications requiring a default safety position when de-energized. Part of the 10-series design, it is engineered for heavy-duty industrial environments that demand high reliability and quiet switching.

Technical Specifications and Performance

The DG4V-5-2A-M-P7-H-7-10 is built for high-duty cycles and precision. Key technical data includes:

  • Mounting Interface: ISO 4401-AC-05-4-A (Nominal Size 05).

  • Spool Configuration: 2A (2-position, single solenoid, spring offset).

  • Maximum Operating Pressure: 31.5 MPa (315 bar).

  • Maximum Flow Rate: Up to 120 L/min (depending on system pressure).

  • Solenoid Voltage: «7» Designator (Standard 240V AC or specific high-voltage AC variant).

  • Special Features: «H» (High-pressure specification), «P7» (Internal pilot/external drain), and «M» (Manual override).

  • Design Number: 10 Series.

Key Features for Industrial Applications

Reliable 2-Position Spring Offset

The «2A» spool arrangement ensures that the valve remains in its offset position via spring force whenever the solenoid is not powered. This provides a predictable fail-safe state for hydraulic actuators, essential for protecting equipment and personnel in the event of an electrical failure or emergency stop.

High-Pressure «H» Capability

With the «H» high-pressure designation, this valve is capable of handling system pressures up to 31.5 MPa. The wet-armature design immerses the solenoid’s moving parts in hydraulic oil, which provides natural lubrication and cooling. This leads to significantly lower switching noise and a much longer service life compared to traditional dry-solenoid valves.

Robust Pilot and Drain Configuration

The P7 configuration (internal pilot with external drain) allows the valve to operate reliably even when the main tank line is subject to high back pressure. By isolating the solenoid drain, the valve ensures consistent shifting times and prevents hydraulic locking, making it suitable for complex manifold systems and high-cycle industrial automation.