Order now the 2094-BC07-M05-S, a high-power 75A Integrated Axis Module (IAM) with Safe Torque Off for advanced Kinetix 6000 systems.
What Is the 2094-BC07-M05-S?
The 2094-BC07-M05-S is a cornerstone of the Rockwell Automation multi-axis motion control platform. This Integrated Axis Module (IAM) combines a high-capacity power supply and a servo drive into a single unit, providing the foundation for the Kinetix 6000 system. The «BC07» designation indicates a high current rating of 75A peak, making it suitable for driving large servo motors in demanding industrial applications. This module not only controls its own axis but also provides regulated DC bus power to additional Axis Modules (AM) on the same power rail, significantly reducing cabinet wiring and the overall footprint of the control system.
Key Technical Specifications
- Input Voltage: 460V AC (3-Phase)
- Continuous Output Current: 45.0A (0-peak)
- Peak Output Current: 75.0A
- Continuous Power Output: 28.0 kW
- Communication: SERCOS interface
- Safety: Integrated Safe Torque Off (STO)
Advanced Safety and Control Logic
The 2094-BC07-M05-S features the -S suffix, which denotes integrated Safety (Safe Torque Off). This hardware-based safety feature allows for the removal of rotational torque from the motor without disconnecting the drive from the power source, meeting SIL3 and PLe safety standards. This is critical for machines requiring frequent operator interaction, as it enables faster restart times after a safety event. The module is fully integrated into the Logix environment, allowing for complex motion profiles and high-speed synchronization across the SERCOS fiber-optic network.
Installation Advice
Given the high current ratings of the 2094-BC07-M05-S, ensure that the power rail and incoming AC power cables are sized correctly for the total load of all axes. Use high-quality fiber optic cables for the SERCOS ring, observing the minimum bend radius to avoid signal attenuation. During installation, verify that the ‘S’ safety header is properly jumpered if you are not using an external safety controller, otherwise, the drive will remain in a permanent safe-off state and will not enable the motor.
Frequently Asked Questions
Q: Can I replace a standard 2094-BC07-M05 with this -S version?
A: Yes, but you must account for the safety wiring requirements. The -S version is physically compatible but requires the safety circuit to be closed to operate.
Q: What motors are compatible with the 2094-BC07-M05-S?
A: It is designed to work with Allen-Bradley MPL, MPM, MPF, and MPS series motors with high-resolution encoders.
Do you need more references from this brand? Explore our full catalog of Allen-Bradley here: https://atlantechdrives.com/manufacturers/allen-bradley/