A9F74106 – Schneider Electric Acti9 iC60N Miniature Circuit Breaker, 1P, 6A, C Curve, In Stock
Buy the Schneider Electric A9F74106, an Acti9 iC60N miniature circuit breaker (MCB), 1-pole, 6 A, C curve, suitable for AC and DC networks, with breaking capacity up to 36 kA and industrial isolation suitability. In stock and available for fast shipping. Get a quote today.
Key Technical Specifications
- Product Type: Miniature circuit breaker (MCB), Acti9 iC60N
- Number of Poles: 1P (1 protected pole)
- Rated Current (In): 6 A
- Tripping Curve: C
- Trip Unit Technology: Thermal-magnetic
- Rated Operating Voltage (Ue): 240 V AC (phase-to-neutral)
- Rated DC Voltage: 12-72 VDC
- Rated Impulse Voltage (Uimp): 6 kV
- Rated Insulation Voltage (Ui): 500 V
- Ultimate Breaking Capacity (Icu): 36 kA (60 VAC); 20 kA (130 VAC); 10 kA (240 VAC); 15 kA (12-48 VDC); 10 kA (72 VDC)
- Rated Short-Circuit Breaking Capacity (Icn): 6 kA
- Service Breaking Capacity (Ics): 27 kA (60 VAC); 15 kA (133 VAC); 7.5 kA (240 VAC); 15 kA (48 VDC); 10 kA (72 VDC)
- Ics as % of Icu: 75% (AC); 100% (DC)
- Module Width: 1 module (18 mm)
- Standards: EN/IEC 60947-2, EN/IEC 60898-1
- Total Lifecycle Carbon Footprint: 8 kg CO2 eq.
Design and Performance
Compact Single-Pole Protection
As the smallest footprint in the iC60N family at just 1 module (18 mm) wide, the A9F74106 offers space-efficient protection for individual circuits, ideal for high-density distribution board layouts.
Multi-Standard Protection in One Device
The iC60N combines circuit protection against short-circuit currents, circuit protection against overload currents, and suitability for industrial isolation per IEC/EN 60947-2 in a single compact device, simplifying circuit protection specification.
Visitrip and VisiSafe for Fast, Safe Fault Handling
The Visitrip system enables fast detection of faulty outgoing circuits for shorter repair times, while the VisiSafe system offers enhanced security when it comes to circuit protection, supporting both speed and safety during fault response.
AC/DC Versatility for Diverse Distribution Needs
Rated for both AC (up to 240 V) and DC (12–72 V) operation, the A9F74106 offers flexibility for distribution applications spanning conventional AC circuits and low-voltage DC systems.
High Short-Circuit Breaking Capacity
With an ultimate breaking capacity up to 36 kA at 60 VAC and a service breaking capacity as high as 100% of Icu on DC circuits, the A9F74106 provides robust fault interruption capability well beyond its compact size would suggest.
Why Buy the A9F74106 From Us
- In stock and ready for immediate dispatch
- Fast shipping on every order
- Commercial advisory support to help you confirm the right Acti9 iC60N rating and curve for your circuit
- Competitive pricing — get a quote in minutes