Burkert 444005 – Type SE35 Inline Flow Transmitter, 4–20 mA 2-Wire + Pulse, Cable Plug
The Burkert 444005 (00444005) is a Type SE35 inline flow transmitter with display. It is the base standard-signal variant of the SE35 range, with these features:
- 12 – 36 V DC supply
- Hall-effect sensor
- 4–20 mA output in 2-wire technology plus a pulse output
- Electrical connection through a DIN EN 175301-803 female cable plug
Mounted with a quarter-turn bayonet on a Bürkert Type S030 inline sensor-fitting, it forms the complete Type 8035 inline paddle-wheel flowmeter for pipes from DN 06 to DN 65.
Simple 2-Wire Loop with Plug Connection
Two features set the 444005 apart within the SE35 family. First, the 4–20 mA output runs as a 2-wire loop, so supply and signal share the same pair. Second, it connects through a standard form A cable plug instead of cable glands. This makes it the quickest SE35 to wire and to swap. The transmitter can be removed from the S030 fitting without opening the pipe or stopping the process. The pulse output, adjustable from 0 to 400 Hz, adds a volume-proportional frequency signal for counters or PLCs.
How the 8035 Measures
As liquid flows through the S030 fitting, it turns a PVDF paddle wheel with four built-in magnets. The Hall sensor in the SE35 detects the rotation through the fitting wall, and the transmitter converts the frequency into flow rate and volume using the fitting’s K factor or an on-site teach-in.
Key Technical Data – Burkert 444005
- Manufacturer article: 444005 / 00444005 – Type SE35 (flowmeter Type 8035 when fitted to S030)
- Supply: 12 – 36 V DC (max. 35 V DC outdoors or in humid environments)
- Current consumption: ≤ 25 mA (variant without relays)
- Analogue output: 4–20 mA, 2-wire, sourcing or sinking. Max. loop impedance 900 Ω at 30 V DC, 600 Ω at 24 V DC. Accuracy ±1 % of range.
- Pulse output: Transistor NPN/PNP, potential-free, 0 – 400 Hz, 5 – 36 V DC, 100 mA
- Sensor: Hall effect
- Electrical connection: Female cable plug to DIN EN 175301-803, for cable 5 – 8 mm and wires 0.25 – 1.5 mm²
- Display: 8-digit alphanumeric LCD, 15 × 60 mm, 3 keys, two totalisers (main and daily)
- Measuring range: 0.3 – 10 m/s (0.5 – 1000 l/min, depending on DN)
- Measurement deviation: ±1 % of reading with teach-in; ±2.5 % with standard K factor
- Linearity / repeatability: ±0.5 % of full scale / ±0.4 % of reading
- Housing: PC
- Degree of protection: IP65 when wired and closed
- Ambient temperature: -10 to +60 °C
- Fluid limits: Set by the S030 fitting, from PN 10 (plastic) to PN 16 (metal) and up to +100 °C
Configuration and Testing
From the keypad you can set language, engineering units, K factor or teach-in, the 4–20 mA range, pulse value and damping. The test menu lets you adjust the 4–20 mA offset and span, read the paddle-wheel frequency, and simulate a flow rate to check the outputs without any actual flow.
Other SE35 Variants
- 570477: UL Recognized version of the 444005
- 444006: same outputs, with 2 cable glands
- 444007: 4–20 mA 3-wire + pulse + 2 relays, cable glands
- 423922: 115/230 V AC supply
- 423921: battery-powered indicator/totaliser, no outputs
- 443360: batch controller
Buy Burkert 444005 from Atlantech Drives
- Genuine Bürkert transmitter, covered by a 12-month warranty
- Fast worldwide shipping
- Senior commercial advice to match supply, outputs and connection to your installation
- Quick, no-obligation quotes. Get a quote today.
Related Bürkert Products
- Burkert 00444007 Inline Flow Transmitter Type SE35 / 8035 – relay version
- Burkert 00423918 Inline Flow Transmitter Type SE35 / 8035
- Burkert 00443396 Inline Flow Sensor Fitting Type S030
- All Burkert products