PPD-11A-3D-Y-Z-74-1 Winner Hydraulics Low-Leakage Proportional Reducing/Relieving Valve for Brake Circuits
The Winner Hydraulics PPD-11A-3D-Y-Z-74-1 combines three properties in a single 11A-3 cartridge: low pressure with no command, a direct-acting, essentially zero-leakage design, and improved dynamic response. Winner states that this low-leakage construction makes the valve suitable for brake circuit applications. Maximum leakage is approximately 20 cc/min, half that of the standard PPD-11A-3D-Y-Z-74. It is rated for 20 L/min at up to 350 bar, can operate below 1 bar, and is covered by US patent US9234605.
Operating Principle
The valve reduces inlet pressure (port 2) to a controlled pressure at port 1. Increasing the coil current raises that reduced pressure proportionally; at zero current it sits at the low end of the range. If pressure at port 1 exceeds the commanded setting, the valve relieves to port 3 (drain) at full flow. Between reducing and relieving the spool closes, minimising oil consumption.
PPD-11A-3D-Y-Z-74-1 Technical Specifications
| Specification | Value |
|---|---|
| Valve type | Direct-acting, spool-type, low-leakage electro-proportional pressure reducing/relieving valve, improved dynamic response |
| Function | Low pressure with no command |
| Cavity | 11A-3 (3-port) |
| Thread | M20 x 1.5 |
| Ports | 1 reduced pressure, 2 inlet, 3 drain |
| Rated flow | 20 L/min (5.28 gpm) |
| Max. operating pressure | 350 bar (5000 psi) |
| Valve hex size | 22.22 mm (7/8 in) |
| Installation torque | 40–50 Nm (30–37 lbf-ft) |
| Max. leakage | Approx. 20 cc/min at port 3 (port 2 at 210 bar, port 1 set to 105 bar) |
| Linearity / repeatability with dither | < 2% / < 2% |
| Hysteresis | < 4% with dither; < 8% with DC input |
| Recommended dither | 100–250 Hz (best 140–200 Hz) |
| Coil | EC-19A, 22 W, 19 mm tube |
| Weight | 0.25 kg without coil / 0.49 kg with coil |
| Patent | US9234605 |
Ordering Code: PPD-11A-3D-Y-Z-74-1
| Y code | Reduced pressure range |
|---|---|
| 3500 | 35–350 bar |
| 2100 | 20–210 bar |
| 1500 | 10–150 bar |
| 1000 | 10–100 bar |
| 0800 | 2–80 bar |
| 0350 | 1–35 bar |
| 0180 | 1–18 bar |
| 0090 | 1–9 bar |
| Z code | Option |
|---|---|
| N | Non-adjustable |
| P | Push-style manual override |
Highlights
- Low leakage: approx. 20 cc/min maximum
- Essentially zero-leakage, direct-acting design that Winner states is suitable for brake circuits
- Reduced pressure rises with current, from low pressure at zero command
- Improved dynamic response for fast, accurate pressure changes
- Full-flow relief from the reduced port to drain
- Operation possible below 1 bar
- Eight operating ranges from 1 bar to 350 bar
- Patented design (US9234605)
- Heat-treated, high-precision ground working parts
- WINNERcoat® zinc-nickel plating, salt-spray tested to DIN EN ISO 9227 for up to 1000 hours
- Pressure rating tested to NFPA T2.6.1, with 90/90 fatigue rating assurance
- 100% functional test before shipment
- Several seal kit materials available
Frequently Asked Questions
How does the PPD-11A-3D-Y-Z-74-1 differ from the PPD-11A-3D-Y-Z-74?
Both share the same cavity, flow, pressure ranges and function (low pressure with no command). The -74-1 is the low-leakage version, at approx. 20 cc/min versus approx. 40 cc/min, and Winner states that it is suitable for brake circuits.
What is the difference between PPD and PPC?
The PPD gives low pressure at zero current, and the pressure rises as current increases. The PPC (e.g. PPC-11A-3D-Y-Z-74-1) works the other way: high pressure at zero current, falling as current increases.
Does back pressure affect the setting?
Yes. According to Winner, back pressure at port 3 adds directly to the valve setting at a 1:1 ratio.
Is there any recommendation at high inlet pressures?
With inlet pressures of 210–350 bar, Winner recommends keeping the reduced pressure at port 1 at a minimum of 30 bar for best control.
11A-3 Proportional Reducing/Relieving Family
| Model | At zero current | Leakage |
|---|---|---|
| PPD-11A-3D-Y-Z-74-1 | Low pressure | Approx. 20 cc/min |
| PPD-11A-3D-Y-Z-74 | Low pressure | Approx. 40 cc/min |
| PPC-11A-3D-Y-Z-74-1 | High pressure | Approx. 20 cc/min |
| PPC-11A-3D-Y-Z-74 | High pressure | Approx. 40 cc/min |
Buy the PPD-11A-3D-Y-Z-74-1 Winner Hydraulics