RP-3A-20-Y-8 Winner Hydraulics 200 L/min | Get a Quote

RP-3A-20-Y-8 Winner Hydraulics: 200 L/min Balanced Piston Relief Main Stage with 8A Control Cavity

For circuits that need more relief capacity than a 10-size cartridge can handle, the Winner Hydraulics RP-3A-20-Y-8 delivers 200 L/min at up to 350 bar in the 3A-2 cavity. The main stage is a pilot-operated balanced piston design with a built-in 8A-2 control cavity, so any 8A-2 pressure control cartridge can be added as the pilot. One cartridge then provides both high-flow relief and flexible pressure setting: manual, remote or electro-proportional.

How Pressure Is Controlled

The 8A-2 pilot cartridge determines the relief setting. As soon as pressure at port 1 overcomes it, the balanced piston pilot-opens port 2 and meters flow from port 1 to port 2 (P to T), keeping system pressure regulated. The pilot setting controls the pressure differential between the two ports. Any back pressure at port 2 adds 1:1 to the setting. Port 2 is rated for full system pressure.

Technical Specifications – RP-3A-20-Y-8

Parameter Value
Valve type Pilot-operated, balanced piston relief, main stage with integral 8A control cavity
Cavity 3A-2
Thread 1.0″-14UNS-2A
Pilot cavity 8A-2
Rated flow 200 L/min (52.83 gpm)
Max. operating pressure 350 bar (5000 psi)
Hex size 28.57 mm (1-1/8 in)
Installation torque 60–70 Nm (44–52 lbf-ft)
Typical response time 10 ms
Max. leakage Approx. 50 cc/min at 70 bar (1000 psi)
Weight 0.17 kg (0.37 lb)
Spring codes (Y) D: 1.7 bar (25 psi) min. control pressure; W: 7 bar (100 psi) min. control pressure

What You Get with the RP-3A-20-Y-8

  • 200 L/min relief capacity from a single screw-in cartridge
  • Integral 8A-2 pilot cavity for flexible pilot selection
  • Two spring codes: D (1.7 bar minimum control pressure) and W (for higher pressure-drop duty)
  • Port 2 rated for full system pressure
  • Stainless-steel filter screen protecting the pilot port
  • Heat-treated, high-precision ground working parts for wear resistance
  • WINNERcoat® zinc-nickel plating, salt-spray tested to DIN EN ISO 9227 for up to 1000 hours
  • NFPA T2.6.1 pressure-rating test, with 90/90 fatigue rating assurance
  • 100% functional test before shipment
  • Choice of seal kit materials

Selection Notes from Winner Hydraulics

  • Not intended for load-holding applications, due to spool leakage.
  • Where high pressure drop may cause cavitation, noise or manifold erosion, Winner recommends the balanced poppet RP-3A-2G-Y-8.
  • For applications that need rapid response and ultra-low leakage, Winner’s RD series is the alternative.

Balanced Piston vs. Balanced Poppet in the 3A-2 Cavity

Feature RP-3A-20-Y-8 RP-3A-2G-Y-8
Main stage Balanced piston Balanced poppet
Rated flow 200 L/min 200 L/min
Max. pressure 350 bar 350 bar
Typical response time 10 ms 7 ms
Max. leakage Approx. 50 cc/min at 70 bar Approx. 0.7 cc/min at reseat
Spring codes D / W B / W

Proportional Pilot Partners

To make the RP-3A-20-Y-8 an electro-proportional relief valve, Winner pairs it with these 8A-2 pilots:

  • PRB-8A-2D-Y-Z, PRB-8A-2C-Y-Z (direct-acting)
  • PRA-8A-2C-Y-Z, PRA-8A-2D-Y-Z-74 (inverse direct-acting)

RP-20-8 Range by Flow

  • 95 L/min: RP-10A-20-Y-8, RP-10W-2S-Y-8, RP-22MA-2S-Y-8
  • 200 L/min: RP-3A-20-Y-8
  • 380 L/min: RP-16A-20-Y-8

Request a Quote for the RP-3A-20-Y-8 Winner Hydraulics

Atlantech Drives supplies original Winner Hydraulics cartridge valves worldwide, with fast shipping. Our commercial team will confirm stock, spring code (D or W), seal material and lead time for the RP-3A-20-Y-8, whether you need one replacement or a production quantity. Get your quote today.

Check Price & Availability!

Get a fast, no-obligation quote for this part.

Our technical team responds within 24-48 hours.

  • Express Worldwide Shipping
  • 100% Genuine OEM Parts

We can supply you this part. Just get in touch!

Logo Pagos Seguros
Trustpilot logoTrustpilot
Great rating
TrustScore 4.4
13 reviews