A9F74210 Schneider Electric – Acti9 iC60N MCB, 2 Pole, 10 A, C Curve, 6000 A / 10 kA at 400 V
The A9F74210 is a double-pole Schneider Electric Acti9 iC60N miniature circuit breaker rated 10 A with a C tripping curve. Both poles are protected and switch together. That makes it the right choice for circuits that need both conductors disconnected at once: phase-to-phase 400 V single-phase loads, 230 V circuits where the neutral must also be switched, IT earthing systems, and DC circuits that need two-pole breaking. Its 10 A C-curve rating suits control transformers, control circuits, small motors and lighting.
A9F74210 Key Data
| Characteristic | Value |
|---|---|
| Range / device | Acti9 iC60 / iC60N |
| Poles | 2P (2 protected poles) |
| Rated current [In] | 10 A |
| Tripping curve | C |
| Trip unit | Thermal-magnetic |
| Networks | AC 50/60 Hz and DC |
| Isolation | Suitable for isolation (IEC/EN 60898-1, 60947-2) |
| Utilisation category | A |
Breaking Capacity: iC60N 2-Pole
| Voltage | Icu (IEC/EN 60947-2) | Ics |
|---|---|---|
| 380–415 V AC | 10 kA | 7.5 kA (75%) |
| 440 V AC | 6 kA | 4.5 kA (75%) |
| 220–240 V AC | 20 kA | 15 kA (75%) |
| 100–133 V AC | 36 kA | 27 kA (75%) |
| 12–60 V AC | 36 kA | 27 kA (75%) |
| ≤ 125 V DC | 10 kA | 10 kA (100%) |
IEC/EN 60898-1 rating: Icn 6000 A at 400 V AC.
Because both poles share the breaking duty, the 2-pole iC60N reaches 20 kA at 230 V, twice the single-pole rating. This is an advantage in boards close to the supply transformer, where fault levels are higher.
Installation
- Width: 36 mm (2 modules), DIN rail mounting
- Busbars: compatible with Acti9 comb busbars at top or bottom
- Indication: trip indicator and positive contact indication
- Accessories: accepts Acti9 auxiliaries such as auxiliary contacts and shunt releases
Environment and Compliance
- Operating temperature: −35 to 70 °C
- Protection: IP20
- Pollution degree: 3
- Standards: IEC/EN 60898-1 and IEC/EN 60947-2
- Sustainability: Schneider Electric Green Premium product
Related Acti9 iC60N 2P References
- A9F77210: iC60N 2P 10 A C-curve breaker listed under another regional reference
- A9F74225: 2P 25 A, C curve
- A9F79220: 2P 20 A, C curve
Buy the A9F74210 Schneider Electric from Atlantech Drives
Atlantech Drives supplies genuine Schneider Electric A9F74210 Acti9 iC60N 2-pole breakers, together with comb busbars and Acti9 auxiliaries, with fast worldwide shipping. Our senior commercial team will confirm the right poles, rating and curve for your circuit and give you a competitive quote quickly.