Buy A9F73332 Schneider Acti9 iC60N MCB 3P 32A Curve B

Purchase now: Schneider Electric A9F73332 Miniature Breaker

Purchase now: Atlantech Drives provides you the Schneider Electric A9F73332, a reliable 3-pole **Miniature Circuit Breaker (MCB)** from the premium **Acti9 iC60N** range. Rated at **32 Amps**, this breaker is distinguished by its **Curve B** tripping characteristic. Unlike the standard Curve C, Curve B is designed to trip faster on short circuits (between 3 and 5 times the nominal current), making it critical for protecting circuits with long cable runs or sensitive equipment like generators.

Technical Specifications and VisiSafe

The A9F73332 offers a breaking capacity of **6000 A** (IEC 60898-1) for residential/commercial use and **10 kA** (IEC 60947-2) for industrial applications at 400V. It features Schneider’s **VisiSafe** green strip, which physically guarantees the contacts are open during maintenance. The **VisiTrip** window turns red to indicate a fault trip, allowing for instant diagnostics separate from a manual switch-off.

  • Part Number: A9F73332.
  • Range: Acti9 iC60N.
  • Poles: 3P.
  • Rated Current: 32 A.
  • Curve: Type B (Magnetic trip 3-5 x In).
  • Breaking Capacity: 6 kA / 10 kA.
  • Voltage: 400 V AC.
  • Width: 54 mm (6 modules of 9mm).
  • Life: 20,000 mechanical cycles.

Expert Tips: When to use Curve B?

Curve C is the default, so why buy Curve B? Expert Tip: Use the A9F73332 (Curve B) when the loop impedance is high (long cables) or the source impedance is high (small generators/UPS). In these scenarios, a short circuit current might not be high enough to trigger a Curve C breaker instantly, leading to melted cables. Curve B ensures safety by tripping at lower fault currents (96A – 160A for this 32A model).

Frequently Asked Questions (FAQs)

Q: Can I use this for motor protection?
A: Generally **No**. The inrush current of a motor (typically 5-7x In) will likely nuisance-trip a Curve B breaker instantly. Use Curve C or D (or a specific Motor Breaker like GV2) for motors.

Q: Is it compatible with Vigi add-on blocks?
A: Yes, you can clip on an **Acti9 Vigi iC60** module to add earth leakage protection (RCD) directly to this breaker, saving DIN rail space.

Do you need more references from this brand? Explore our full catalog of Schneider Electric here.

Check Price & Availability!

Get a fast, no-obligation quote for this part.

Our technical team responds within 24-48 hours.

  • Express Worldwide Shipping
  • 100% Genuine OEM Parts

We can supply you this part. Just get in touch!

Logo Pagos Seguros